Influence of internal relative efficiency of steam turbine compartments on the performance of steam turbine cogeneration plant
The paper considers a steam turbine cogeneration plant that includes a back-pressure steam turbine and a natural gas-fired steam boiler that enables exhaust gas heat recovery, which is rather promising for the isolated heat and electricity consumers. A design and verification mathematical model of the steam turbine plant was developed. The focus is made on the optimization studies into the effect of the relative efficiency of turbine compartments on the performance indices of the steam turbine cogeneration plant with an installed electric capacity of 50 MW that uses the heat of steam contained in the combustion products of the boiler for heating the feed-water of the heat network. © 2018 The Authors, published by EDP Sciences.
Библиографическая ссылка
Stepanova E., Maksimov A. Influence of internal relative efficiency of steam turbine compartments on the performance of steam turbine cogeneration plant // E3S Web of Conferences. Vol.69. ID: 02006. 2018. DOI: 10.1051/e3sconf/20186902006